E145 ELECTRONIC BOARD
Model: E145
Mains supply voltage: Switching power supply from 90V~ to 260V~ 50(60) Hz
Max power: 4W Stand by, <2W with sleep function (programmable from PC/MAC) W
Max motor power: 800 W
Max accessories load: 500 mA 24V - 500 mA BUS 2easy
Max electric lock load: FAAC lock (12V~ - 24V ) - not FAAC 24V - 500 mA
Programming mode: LCD display and buttons, via PC/MAC via USB-B connection
Status signaling: LCD and LED display
Terminal board inputs: Open, Open pedestrian leaf, Stop (closed), BUS 2easy, Opening safety devices, Closing safety devices, Power + Earth, Opening and closing limit switches
Terminal block outputs: Flashing light, Motors, 24V accessory power supply, 2 programmable OUTPUTS (default: warning light and fail-safe), 2 electric locks
Quick connector: XF 433/868 module for OmniDEC decoding, connector for DECODER/MINIDEC/RP, USB-A, USB-B
Protection fuses: 1 (10A)
Operating ambient temperature: -20°C ÷ +55°C
Mod. 790076
For 230V 560 hydraulic actuator