12-24V dual-channel detector for DIN rail mounting
Mod. BASIC-DGL
Power supply: 12-24Vac/dc
Power consumption: 80mA
Loop inductance: from 30µH. Ideal: from 80µH to 500µH Loop wiring: max. length 100m, 1,5mm, minimum 50 twists/m Loop resistance: <8O with power supply cable
Frequency range: 20-80 KHz across 4 levels
Power supply: 12-24Vac/dc
Power consumption: 80mA
Loop inductance: from 30µH. Ideal: from 80µH to 500µH Loop wiring: max. length 100m, 1,5mm, minimum 50 twists/m Loop resistance: <8O with power supply cable
Frequency range: 20-80 KHz across 4 levels
Sensitivity range: from 0,01% to 0,65% (∆f/f) across 4 levels
Relay output: OUT1 SP relay 5(1) A 250 Vac / OUT2 SP relay 5(1) A 250 Vac Detection type: pulse (100ms) and/or presence for each output Connections: removable terminal blocks
Indicators: 1 red LED + 1 green LED
Data retention: EEPROM memory
Housing: plastic, 111x28x92,5mm
Mounting: DIN - OMEGA rail
Front protection rating: IPOO
Operating conditions: ambient temperature: -10/+50°C - storage temperature: -20/+70°C
Relative humidity: 30/80% ambient, non-condensing
Plus:
· 10 sensitivity levels
· Operating logic selection (loop 1 only / loops 1-2 independent / with or without direction detection)
· Displays the operating frequency of each loop
· Loop frequency stability check function to verify correct installation
· Dynamic release function
24-month warranty