Shipping
Shipping in 5-10 business days
Description
FIRE ALARM SYSTEM KIT 2 HEAT DETECTORS 1 SMOKE DETECTOR FIRE DOOR RELEASE BUTTON REI SOS SIREN GSM EMERGENCY CALL - SV-KRGBPREISA
Model SV-KRGBPREISA
SKU: SV-KRGBPREISA
SV-KRGBPREISA fire alarm system kit for boiler rooms and adjacent premises. Consisting of: 1) Microprocessor-based conventional fire alarm control panel with 2 zones. Each zone supports 20 active detectors (individual detector standby current 50 ?A, alarm current 25 mA); plus 12 passive devices, up to a maximum of 32 sensors; such as call points. For a total of 64 sensors. Barriers, provided they are not powered by the zone. Individual event indication by LED. Three access passwords for control and operation at three different authority levels. Zone programming (using the front panel buttons) in the following modes: pre-alarm, alarm, test, maintenance. Silenceable and excludable outputs: sirens, telephone call. 2 O.C. outputs. Zone alarm repetition. 2 fire alarm and fault relay outputs. 2 supervised fire pre-alarm outputs. 24Vdc auxiliary power supply. 220 V power supply. 50/60 Hz. Buffer battery charger, 27.6 V. 1.5 A. Operating temperature from - 5° to + 45°C. Humidity 95 %. IP 40 protection. Painted metal enclosure. Dimensions L350XH290XP95 mm. Weight 3.5 Kg. Certified to EN54-2, EN54-4 CPD. 1) Fiamm batteries, 12 V. 1.2 Ah. 1) 62° C rate-of-rise heat detector. 1) Tyndall-effect smoke detector. 1) Multi-criteria rate-of-rise heat and Tyndall-effect smoke detector. 1) Resettable manual call point. 1) Lamp with mini siren and flashing “Fire Alarm” sign. 1) REI door-holding electromagnet, 50 Kg holding force. 1) Self-powered external flashing siren with 2 Fiamm batteries, 12 V. 1.2 Ah. 1) GSM telephone dialer, calls 10 numbers and plays a recorded message. Product assembled and selected at the Securvera facility in Rome. Guaranteed in accordance with the law against manufacturing defects and faults
CE COMPONENT LIST FOR EXPANDING OR INSTALLING A FIRE ALARM SYSTEM IN ACCORDANCE WITH THE LAW:
01 SF-CFD Conventional Fire Alarm Control Panel, 2 Zones, EN54-2 EN54-4 CPD. Controls: 64 sensors. Control outputs for alarm, activation and REI doors
02 SF-172 Fiamm 12 V. 7.2 Ah buffer battery, L181XH176XP76 mm, Valve Regulated AGM VRLA, charged and selected by Securvera
01 SV-RTC Conventional fixed-temperature detector, 62° C threshold. Current draw 50 µA, alarm current 25 mA. Plug-in mounting. Output for remote indicator
01 SV-RFA Conventional Tyndall-effect smoke detector. Current draw 50 µA, alarm current 25 mA. Plug-in mounting. With 14 mA OC output for remote indicator
01 SV-RFT Multi-criteria Tyndall-effect smoke and fixed-temperature detector, 62 ° C. Current draw 50 µA, alarm current 25 mA. Plug-in base. 14 mA OC output
01 SV-P5R Red resettable conventional manual call point. Manual fire emergency call point; remains in alarm until reset. IP 40
01 SF-LMP LED lamp and sounder, 85 dB, with backlit “Fire Alarm” sign (replaceable). Wall-mounted fire alarm system component
01 SF-LRS Optical and audible event repeater, LED + 50 dB buzzer. 12 and 28 Vdc power supply. Current draw 22 mA. Connect to detector OC output
01 SF-BE5 White fire door-holding electromagnet, R.E.I. 24 Vdc power supply. Current draw 50 mA. Holding force 50 Kg. With release button
01 SV-DF2 Red LED flashing siren, self-powered, external, adjustable alarm duration for fire alarm, 110 dB. 12 and 24 Vdc power supply. IP 31 EN54-3
01 SF-112 Fiamm 12 V. 1.2 Ah buffer battery, L97XH50XP48,5 mm. Valve Regulated AGM VRLA, charged and selected by Securvera
01 SV-CAG GSM telephone dialer. 1 alarm input; calls and plays a message to 10 numbers. 1 voltage-free relay for remote activation of an intervention
01 SV-GAR Warranty certificate; Securvera manufacturer's warranty as required by law: 24 months; qualified installation in accordance with D.M.37/2008 for life
01 SV-IST Instructions with detailed installation specifications. Current fire safety regulations on risk assessment must be followed
Securvera Registered Trademark 663069: Automation, Access Control, Wired and Wireless Alarm Sensors, Fire Alarm Systems
Instructions or Installation Manual: Find it below under “CLICK TO GET THE GUIDE OR MANUAL”
Use and Application: Boiler Room Fire Alarm System Kit, Emergency Response and Extinguishing
Italian Manufacturer of CE Products: Fire Alarm Control Panels, Smoke and Heat Detectors, Badenie Sirens
Electrical Protection Against Stress: Reverse Polarity, Sensor Presence Monitoring, Line Isolators
Country of Origin and Manufacture: Made in Italy at the Securvera factory and carefully selected
Payment Methods: State tax deductions or tax accounting via traceable bank transfer
Warranty Beyond the Statutory Period: Lifetime Securvera warranty against manufacturing defects and faults
Compatibility with Other Brands: Conventional smoke, flame, heat and Badenie detectors and systems
Installation Instructions Manual: Read the manual carefully for weights, dimensions, functions and required accessories
Item Code, Model, Type: SV-KRGBPREISA Fire Alarm System Kit for Boiler Room Monitoring
CLICK HERE TO DOWNLOAD THE MANUAL OR PRACTICAL DIY GUIDE:
MANUFACTURER'S MANUAL
24-month warranty