Shipping
Shipping in 5-10 business days
Description
FARMHOUSE FIRE ALARM SYSTEM KIT 4 SMOKE DETECTORS 3 BREAK-GLASS CALL POINTS 2 EVENT REPEATERS EXTERNAL FLASHING SIREN GSM SOS - SV-RLBRBSLGNC
Mod. SV-RLBRBSLGNC
SKU: SV-RLBRBSLGNC
SV-RLBRBSLGNC fire alarm system kit for farmhouse, pizzeria, bakery and adjoining premises. Comprising: 1) Microprocessor-based conventional fire alarm control panel with 6 zones. Each zone supports 20 active detectors (individual detector standby current 50 ?A; alarm current 25 mA), plus 12 passive devices, up to a maximum of 32 sensors, such as call points. For a total of 64 sensors. Barriers, provided they are not powered by the zone. Individual event LED indication. Three access passwords for control and operation at three different authority levels. Programming (using the front panel buttons) of zones in pre-alarm, alarm, test and maintenance modes. Outputs for sirens and telephone calls can be silenced and disabled. 2 O.C. outputs for zone alarm repetition. 2 relay outputs for fire alarm and fault. 2 supervised fire pre-alarm outputs. 24 Vdc auxiliary power supply. 220 V, 50/60 Hz power supply. Standby battery charger, 27.6 V, 1.5 A. Operating temperature from - 5° to + 45°C. Humidity 95%. IP 40 protection. Painted metal enclosure. Dimensions L350XH290XP95 mm. Weight 3.5 Kg. Certified to EN54-2, EN54-4 CPD. 2) Fiamm batteries, 12 V, 7.2 Ah. 4) Tyndall-effect smoke detectors. 1) Fixed-temperature rate-of-rise detector, 62° C. 3) Resettable manual call points. 2) Flashing lamps with sounder and "Fire Alarm" text. 2) Optical and acoustic event repeaters, LED + buzzer, 50 dB, 12 and 28 Vdc power supply. 1) Programmable electronic siren or bell with flashing FIRE text, 90 dB, for indoor use; 24 Vdc power supply. IP 31. 1) External self-powered flashing siren with 1 Fiamm battery, 12 V, 2 Ah. 1) GSM SOS call unit, telephone dialler with 4 alarm messages and 4 intervention commands. Product assembled and selected at the Securvera facility in Rome. Guaranteed in accordance with the law against manufacturing defects and faults
LIST OF CE COMPONENTS FOR EXPANDING OR INSTALLING A FIRE ALARM SYSTEM IN ACCORDANCE WITH THE LAW:
01 SF-CFS Conventional Fire Alarm Control Panel, 6 Zones, EN54-2 EN54-4 CPD. Manages: 192 sensors; control outputs for alarms, intervention and fire doors
02 SF-172 Fiamm battery, 12 V, 7.2 Ah. Standby accumulator, L181XH176XP76 mm, Valve Regulated AGM VRLA, charged and selected by Securvera
04 SV-RFA Conventional Tyndall-effect smoke detector. Current draw: 50 µA; alarm current: 25 mA. Plug-in mounting. With 14 mA OC output for repeater
01 SV-RTC Conventional fixed-temperature detector, 62° C threshold. Current draw: 50 µA; alarm current: 25 mA. Plug-in mounting. Repeater output
03 SV-P5R Conventional resettable manual call point, red. Manual fire emergency call point; remains in alarm until reset. IP 40
02 SF-LMP LED and acoustic lamp, 85 dB, with backlit "Fire Alarm" text (replaceable). Wall-mounted fire alarm system device
02 SF-LRS Optical and acoustic event repeater, LED + buzzer, 50 dB, 12 and 28 Vdc power supply, current draw 22 mA. Connect to detector OC output
01 SF-SIR Programmable electronic siren or bell with illuminated FIRE text, 90 dB, signals fire; power supply: 24 Vdc. Current draw: 120 mA. IP 31 EN54-3
01 SV-DF2 Red LED flashing external self-powered siren, adjustable alarm duration, for fire alarms, 110 dB. Power supply: 12 and 24 Vdc. IP 31 EN54-3
01 SF-120 Fiamm battery, 12 V, 2.2 Ah. Standby accumulator, L178XH34XP60 mm. Valve Regulated AGM VRLA, charged and selected by Securvera
01 SS-GNC GSM telephone dialler. 4 alarm inputs; calls 10 numbers per channel with one message. 4 outputs for remote activation of interventions
01 SV-GAR Warranty certificate; Securvera manufacturer's warranty in accordance with the law: 24 months; lifetime qualified installation in compliance with Italian Ministerial Decree 37/2008
01 SV-IST Detailed installation instructions. Current fire safety regulations and risk assessment requirements must be followed
Securvera Registered Trademark 663069: Gate automation, access control, wired and wireless alarm sensors, fire alarm systems
Instructions or Installation Manual: See below for "CLICK TO GET THE GUIDE OR MANUAL"
Use and application: Fire alarm system control panel, alarm activation, intervention and shutdown
Italian manufacturer of CE products: Fire alarm control panels, smoke and heat detectors, sirens
Electrical protection against stress: Polarity reversal, sensor alive monitoring, line isolators
Country of origin and manufacture: Made in Italy at the Securvera factory and carefully selected
Payment methods: State tax deductions or tax accounting via traceable bank transfer
Warranty beyond the statutory period: Securvera lifetime product warranty against manufacturing defects and faults
Compatibility with other brands: Smoke, flame and heat detectors for conventional systems
Installation instruction manual: Read the manual carefully for weights, dimensions, functions and required accessories
Item code, model, type: SV-RLBRBSLGNC component kit for farmhouse fire alarm systems