Shipping
Shipping in 5-10 business days
Description
CONVENTIONAL FIRE ALARM SYSTEM KIT FOR OFFICE, WORKSHOP AND BOILER ROOM, WITH HEAT AND SMOKE DETECTORS, MANUAL CALL POINTS, INTERNAL AND EXTERNAL SIRENS - SV-RLBRBQLGNB
Mod. SV-RLBRBQLGNB
SKU: SV-RLBRBQLGNB
SV-RLBRBQLGNB fire alarm system kit for a boiler room and adjacent rooms. Consisting of: 1) Microprocessor-based conventional fire alarm control panel with 2 zones. Each zone supports 20 active detectors (individual detector current consumption: 50 ?A in standby, 25 mA in alarm); plus 12 passive devices, up to a maximum of 32 sensors, such as manual call points. For a total of 64 sensors. Barriers, provided they are not powered by the zone. Individual event indication by LED. Three access passwords for monitoring and control at three different authority levels. Zone programming (using the front panel buttons) in the following modes: pre-alarm, alarm, test, maintenance. Silenceable and excludable outputs: sirens, telephone call. 2 O.C. outputs. Zone alarm repeat. 2 relay outputs for fire alarm and fault. 2 supervised fire pre-alarm outputs. 24Vdc auxiliary power supply. 220 V power supply. 50/60 Hz. Buffer battery charger, 27,6 V. 1,5 A. Operating temperature from - 5° to + 45°C. Humidity 95 %. IP 40 protection. Painted metal enclosure. Dimensions L350XH290XP95 mm. Weight 3,5 Kg. Certified to EN54-2, EN54-4 CPD. 2) Fiamm batteries, 12 V. 7,2 Ah. 1) Rate-of-rise heat detector, 62° C. 1) Tyndall-effect smoke detector. 2) Resettable manual call points. 1) Optical and audible event repeater, LED + 50 dB buzzer, 12 and 28 Vcc power supply. 1) Lamp with mini siren and flashing “Fire Alarm” sign. 1) REI door-holding electromagnet, pull force 50 Kg. 1) Programmable electronic siren or bell with flashing FIRE sign, 90 dB; 24 Vcc power supply. IP 31. 1) Self-powered external flashing siren with 1 Fiamm battery, 12 V. 2 Ah. Product assembled and selected at the Securvera factory in Rome. Guaranteed by law against manufacturing defects and faults
LIST OF CE-COMPLIANT COMPONENTS FOR THE EXPANSION OR INSTALLATION OF A FIRE ALARM SYSTEM IN ACCORDANCE WITH THE LAW:
01 SF-CFD Conventional Fire Alarm Control Panel, 2 Zones, EN54-2 EN54-4 CPD. Manages: 64 sensors. Control outputs for alarms, activation and REI doors
02 SF-172 Fiamm battery, 12 V. 7,2 Ah, standby accumulator, L181XH176XP76 mm, Valve Regulated AGM VRLA, charged and selected by Securvera
01 SV-RTC Conventional fixed-temperature detector, 62° C threshold. Current consumption 50 µA in standby, 25 mA in alarm. Plug-in mounting. Output for repeater
01 SV-RFT Multicriteria smoke detector, Tyndall effect and fixed temperature 62 ° C. Current consumption 50 µA in standby, 25 mA in alarm. Plug-in base. OC output 14 mA
01 SV-RFA Conventional Tyndall-effect smoke detector. Current consumption 50 µA in standby, 25 mA in alarm. Plug-in mounting. With 14 mA OC output for repeater
02 SV-P5R Conventional resettable manual call point, red. Manual emergency request for fire. Remains in alarm until reset. IP 40
01 SF-LMP LED lamp and sounder, 85 dB, with backlit “Fire Alarm” sign (replaceable). Wall-mounted for fire alarm systems
01 SF-LRS Optical and audible event repeater, LED + 50 dB buzzer, 12 and 28 Vcc power supply. Current consumption 22 mA. Connect to the detector's OC output
01 SF-BE5 White fire-door holding electromagnet, R.E.I. 24 Vcc power supply. Current consumption 50 mA. Pull force 50 Kg. With release button
01 SF-SIR Programmable electronic siren or bell with illuminated FIRE sign, 90 dB, fire alarm indication; 24 Vcc power supply. Current consumption 120 mA. IP 31 EN54-3
01 SV-DF2 Red LED flashing siren, self-powered, external, adjustable alarm duration for fire alarm, 110 dB. 12 and 24 Vcc power supply. IP 31 EN54-3
01 SF-120 Fiamm battery, 12 V. 2 Ah, standby accumulator, L178XH34XP60 mm. Valve Regulated AGM VRLA, charged and selected by Securvera
01 SV-GAR Warranty certificate; Securvera manufacturer's warranty as required by law: 24 months; lifetime qualified installation in accordance with D.M.37/2008
01 SV-IST Detailed assembly instructions and specifications. Current fire safety regulations concerning risk assessment must be followed
Securvera Registered Trademark 663069: Automation, access control, wired and wireless alarm sensors, fire alarm systems
Instructions or Installation Manual: See below for “CLICK TO GET THE GUIDE OR MANUAL”
Use and functions: Fire alarm system control panel, activation, intervention and shutdown
Italian manufacturer of CE products: Fire alarm control panels, smoke and heat detectors, sirens
Electrical protection against stress: Reverse polarity, sensor heartbeat monitoring, line isolators
Country of origin and manufacture: Made in Italy at the Securvera factory and carefully selected
Payment methods or systems: State tax deductions or tax accounting via traceable bank transfer
Warranty beyond the statutory period: Product guaranteed by Securvera for life against manufacturing defects and faults
Compatibility with other brands: Smoke, flame and heat detectors for conventional systems
Installation instruction manual: Read the manual carefully for weights, measurements, functions and required accessories
Item code, model, type: SV-RLBRBQLGNB Fire Alarm System Kit for Workshop and Office Protection
CLICK HERE TO DOWNLOAD THE MANUAL OR PRACTICAL DIY GUIDE:
MANUFACTURER'S MANUAL
24-month warranty
eb: 374049610597