SV-RLBRBSLGNA Fire alarm system kit for a dental practice and adjoining premises. Comprises: 1) Microprocessor-based conventional fire alarm control panel with 6 zones. Each zone supports 20 active detectors (individual detector standby current 50 ?A, alarm current 25 mA); plus 12 passive devices, up to a maximum of 32 sensors, such as call points. For a total of 64 sensors. barriers, provided they are not powered by the zone. Single-event LED indication. Three access passwords for control and operation at three different authority levels. Zone programming (using the front-panel keys) in the following modes: pre-alarm, alarm, test, maintenance. Silenced and disabled outputs for: sirens, telephone calls. 2 O.C. outputs. Zone alarm repetition. 2 fire alarm and fault relay outputs. 2 supervised fire pre-alarm outputs. 24 Vdc auxiliary power supply. 220 V, 50/60 Hz power supply. Standby battery charger, 27.6 V, 1.5 A. Operating temperature from - 5° to + 45°C. Humidity 95%. IP 40 protection. Painted metal enclosure. Dimensions L350XH290XP95 mm. Weight 3.5 Kg. Certified to EN54-2, EN54-4 CPD. 2) Fiamm batteries, 12 V, 7.2 Ah. 1) 62° C rate-of-rise heat detector. 1) Tyndall-effect smoke detector. 1) Multicriteria rate-of-rise heat and Tyndall-effect smoke detector. 1) Linear smoke detector, 8 to 100 Metres, covered area L. 7+7 Metres, power supply 12/28 Vdc, current consumption 35 mA. Opto-relay output 1 A. 2) Resettable manual call points. 1) Resettable manual call point. 1) Lamp with miniature siren and flashing “Fire Alarm” sign. 1) Optical and audible event repeater, LED + buzzer, 50 dB, power supply 12 and 28 Vdc. 1) R.E.I. fire door holding electromagnet, holding force 50 Kg. 1) Percussion bell, 90 dB sounder. IP 34. 1) Programmable electronic siren or bell with flashing FIRE sign, 90 dB, for indoor use; 24 Vdc power supply. IP 31. 1) External self-powered flashing siren with 1 Fiamm battery, 12 V, 1.2 Ah. 1) GSM SOS call unit, telephone dialler with 4 alarm messages and 4 activation commands. Product assembled and selected at the Securvera facility in Rome. Guaranteed by law against manufacturing defects and faults
CE COMPONENT LIST FOR EXPANDING OR INSTALLING A FIRE ALARM SYSTEM IN COMPLIANCE WITH THE LAW:
01 SF-CFS Conventional Fire Alarm Control Panel, 6 Zones, EN54-2 EN54-4 CPD. Manages: 192 sensors, control outputs for alarms, activation and R.E.I. doors
02 SF-172 Battery 12 V, 7.2 Ah Fiamm, standby accumulator, L181XH176XP76 mm, Valve Regulated AGM VRLA, charged and selected by Securvera
01 SV-RFA Conventional Tyndall-effect smoke detector. Current consumption 50 µA, alarm current 25 mA. Plug-in mounting. With 14 mA OC output for repeater
01 SV-RFT Multicriteria Tyndall-effect smoke and fixed-temperature 62° C detector. Current consumption 50 µA, alarm current 25 mA. Plug-in base. 14 mA OC output
01 SF-EEV Linear smoke detector, 8 to 100 Metres, covered area L. 7+7 Metres, power supply 12/28 Vdc, current consumption 35 mA. Opto-relay output 1 A
01 SV-P5R Resettable Conventional Manual Call Point, Red. Manual fire emergency call point. Remains in alarm until reset. IP 40
01 SF-LMP LED and audible alarm, 85 dB, with backlit “Fire Alarm” sign (replaceable). Wall-mounted fire alarm system device
01 SF-LRS Optical and audible event repeater, LED + buzzer, 50 dB, power supply 12 and 28 Vdc, current consumption 22 mA. Connect to detector OC output
01 SF-BE5 Fire Door Holding Electromagnet, R.E.I., White, 24 Vdc power supply, current consumption 50 mA, holding force 50 Kg, with release button
01 SF-CBC Red Badenia or electromechanical bell, 95 dB, fire alarm indication, 24 Vdc power supply, current consumption 50 mA, dimensions ø152XS55 mm.
01 SF-SIR Programmable electronic siren or bell with illuminated FIRE sign, 90 dB, fire alarm indication; 24 Vdc power supply, current consumption 120 mA, IP 31 EN54-3
01 SV-DF2 Red external self-powered LED flashing siren, adjustable timer for fire alarm, 110 dB, 12 and 24 Vdc power supply, IP 31 EN54-3
01 SF-112 Battery 12 V, 1.2 Ah Fiamm, standby accumulator, L97XH50XP48,5 mm, Valve Regulated AGM VRLA, charged and selected by Securvera
01 SS-GNC GSM telephone call unit. 4 alarm inputs, calls 10 numbers per channel with a message. 4 outputs for remote activation of actions
01 SV-GAR Warranty Certificate; Securvera manufacturer’s warranty as required by law: 24 months; lifetime warranty when installed by a qualified installer in compliance with D.M.37/2008
01 SV-IST Detailed installation instructions. Current fire safety regulations and risk assessment requirements must be followed
Securvera Registered Trademark 663069: Automation, Access Control, Wired and Wireless Alarm Sensors, Fire Alarm Systems
Instructions or Installation Manual: See below for “CLICK TO GET THE GUIDE OR MANUAL”
Use and Functions: Fire Alarm System Control Panel, Activation, Response and Shutdown
Italian Manufacturer of CE Products: Fire Alarm Control Panels, Smoke and Heat Detectors, Badenia Bells, Sirens
Electrical Stress Protection: Reverse Polarity, Sensor Life Monitoring, Line Isolators
Country of Origin and Manufacture: Made in Italy at the Securvera factory and carefully selected
Payment Methods: State tax deductions or tax accounting via traceable bank transfer
Warranty Beyond the Statutory Period: Product covered by Securvera’s lifetime warranty against manufacturing defects and faults
Compatibility with Other Brands: Smoke, flame and heat detectors, Badenia bells, conventional systems
Installation Instructions Manual: Read the manual carefully for weights, dimensions, functions and required accessories
Article Code, Model, Type: SV-RLBRBSLGNA Fire Alarm System Kit for Dental Practice Monitoring
CLICK HERE TO DOWNLOAD THE DIY MANUAL OR PRACTICAL GUIDE:
MANUFACTURER’S MANUAL
24-month warranty
eb: 234532682467