Conventional Fire System Kit Hotel Office Securvera Sv-rlbrbqlgnc

Save £49.00

Model: eb-234532684346
Warranty: 24 months
Supplier: Securvera
Price:
£937.00 £986.00

Do you need help with this product? Contact us
Whatsapp-Share

Share this product
Email-Share Whatsapp-Share Facebook-Share Copy-Share

Shipping

shipping in 10 working days

Description

CONVENTIONAL FIRE FIGHTING SYSTEM KIT HOTEL OFFICE HEATING CENTRAL HEAT SMOKE DETECTORS INTERNAL EXTERNAL SIREN BUTTONS - SV-RLBRBQLGNC

Mod. SV-RLBRBQLGNC

SKU: SV-RLBRBQLGNC

SV-RLBRBQLGNC Fire prevention system kit for boiler room and adjacent rooms. Consisting of: 1) Conventional microprocessor fire control unit with 2 zones. Each zone supports 20 active detectors (Single detector standby absorption 50 μA in alarm 25 mA); plus 12 passive, up to a maximum of 32 sensors; as buttons. For a total of 64 sensors. barriers, as long as it does not feed from the area. LED single event signaling. Three passwords for control and command access on three different levels of authority. Programming (via buttons on the front panel) zones in modes: pre-alarm, alarm, test, maintenance. Silenceable and excludable outputs: sirens, telephone call. 2 OC outputs. Zone alarm repetition. 2 fire and fault alarm relay outputs. 2 supervised fire pre-alarm outputs. 24Vdc auxiliary power supply. Power supply 220 V. 50/60 Hz. Battery charger in buffer, 27.6 V. 1.5 A. Working temperature from - 5° to + 45°C. Humidity 95%. IP 40 protection. Painted metal container. Dimensions L350XH290XP95 mm. Weight 3.5 kg. Certified EN54-2, EN54-4 CPD. 1) Fiamm 12 V. 2 Ah batteries. 1) Tyndall effect smoke detector. 1) Multi-criteria thermo-velocimetric detector and Tyndall effect smoke. Linear Smoke Detector from 8 to 100 Meters Covered Area L. 7+7 Meters Power supply 12/28 Vdc Absorption 35 mA. Optorelè output 1 A. 2) Resettable manual buttons. 1) LED Optical and Sound Event Repeater + 50 dB Buzzer Power supply 12 and 28 Vdc. 1) Lamp with little siren and flashing fire alarm writing. 1) REI door lock electromagnet Traction force 50 Kg. 1) Programmable electronic siren or bell Flashing writing FIRE 90 dB from indoors; 24 Vdc power supply. IP 31. 1) External self-powered flashing siren with 1 Fiamm 12 V. 2 Ah battery. Product assembled and selected in the Securvera Roma factory. Guaranteed by law against defects and manufacturing defects


LIST OF CE COMPONENT(S) FOR THE EXPANSION OR CONSTRUCTION OF A FIRE ALARM SYSTEM IN ACCORDANCE WITH THE LAW:
01 SF-CFD Conventional Fire Control Panel 2 Zones EN54-2 EN54-4 CPD Manages: 64 Sensors. Command Outputs for Alarm and Intervention and REI Doors
02 SF-172 Battery 12 V. 7.2 Ah Fiamm Buffer Accumulator L181XH176XP76 mm Valve Regulated AGM VRLA Charged and Selected by Securvera
01 SV-RFA Conventional Smoke Detector Tyndall Effect Absorption. 50 µA in Alarm 25 mA Plug-in fixing. With 14 mA OC Output for Repeater
01 SV-RFT Multicriteria Smoke Detector Tyndall Effect and Fixed Temperature 62 ° C. Absorb. 50 µA in Alarm 25 mA Plug-in base. OC 14 mA output
01 SE-FBI Linear Smoke Detector from 8 to 100 Meters Covered Area L. 7+7 Meters Power supply 12/28 Vdc Absorption 35 mA. 1 A optorelay output
02 SV-P5R Conventional Resettable Manual Button, Red. Manual Emergency Request for Fire Remains in Alarm until Reset IP 40
01 SF-LMP LED and Acoustic Lamp 85 dB with Backlit Fire Alarm Writing (Replaceable). Wall installation for fire prevention system
01 SF-LRS Optical and Sound Event Repeater LED + Buzzer 50 dB Power supply 12 and 28 Vdc Absorption 22 mA to be connected to the OC output detector
01 SF-BE5 REI fire door lock electromagnet White color Power supply. 24 Vdc. Absorb. 50 mA Traction Force 50 Kg. C/Release Button
01 SF-SIR Programmable Electronic Siren or Bell Written FIRE Bright 90 dB Signals Fire; Food 24 Vdc. Absorb. 120 mA IP 31 EN54-3
01 SV-DF2 External Self-powered Red LED Flashing Siren Timed. Adjustable for Fire Alarm 110 dB Power. 12 and 24 Vdc. IP 31 EN54-3
01 SF-120 Battery 12 V. 2.2 Ah Fiamm Buffer battery L178XH34XP60 mm. Valve Regulated AGM VRLA Loaded and Selected by Securvera
01 SV-GAR Guarantee Certificate; Securvera Manufacturer's Warranty As per Law: 24 Months; Qualified Installation Compliant with DM37/2008 for life
01 SV-IST Detailed Instructions for Assembly. Current fire prevention regulations on risk assessment must be respected


Securvera Registered Trademark 663069: Automated Entrance Control Sensors Alarm Wire and Fire Radio
Instructions or Installation Manual: You will find under the writing "CLICK TO GET THE GUIDE OR MANUAL"
Use Application Functions: Fire Alarm System Activation Intervention Shutdown
Italian Manufacturer CE Products: Fire Alarm Control Panels Smoke Sensors Temperature Badenie Sirens
Electrical Stress Protection: Polarity Reversal Live Existence Control Line Isolator Sensors
Country of origin and Manufacture: Made in Italy in the Securvera factory and Carefully Selected
Payment Forms or Systems: State Deductions or Tax Accounting via Traceable Bank Transfer
Warranty Beyond the Legal Terms: Product Guaranteed by Securvera for Life Against Factory Defects and Defects
Compatibility other brands: Badenie Smoke Flame Temperature Detectors Conventional Systems
Installation Instruction Manual: Read the Manual Weights Measurements Functions Necessary Accessories Carefully
Article Code Model Type: SV-RLBRBQLGNC Fire Fighting System Kit for Workshop and Office Control


CLICK HERE TO DOWNLOAD THE MANUAL OR PRACTICAL DIY GUIDE:
MANUFACTURER'S MANUAL

24 month warranty