SV-RLBRBQLGNC fire alarm system kit for boiler rooms and adjoining premises. Consisting of: 1) Microprocessor-based conventional fire alarm control panel with 2 zones. Each zone supports 20 active detectors (individual detector current consumption: 50 ?A in standby, 25 mA in alarm), plus 12 passive devices, up to a maximum of 32 sensors, such as manual call points. For a total of 64 sensors. Beam detectors, provided they are not powered by the zone. LED indication of each event. Three access passwords for control and operation at three different authority levels. Zone programming (via front panel buttons) in pre-alarm, alarm, test and maintenance modes. Silenceable and disableable outputs: sirens, telephone dialler. 2 O.C. outputs. Zone alarm repetition. 2 relay outputs for fire alarm and fault. 2 supervised fire pre-alarm outputs. 24 Vdc auxiliary power supply. 220 V, 50/60 Hz power supply. Standby battery charger, 27.6 V, 1.5 A. Operating temperature from - 5° to + 45°C. Humidity 95%. IP 40 protection. Painted metal enclosure. Dimensions L350XH290XP95 mm. Weight 3.5 kg. Certified to EN54-2, EN54-4 CPD. 1) Fiamm 12 V, 2 Ah batteries. 1) Tyndall-effect smoke detector. 1) Multicriteria rate-of-rise heat and Tyndall-effect smoke detector. Linear smoke detector for 8 to 100 metres, covered area L. 7+7 metres, power supply 12/28 Vdc, current consumption 35 mA. Opto-relay output 1 A. 2) Resettable manual call points. 1) Optical and audible event repeater, LED + 50 dB buzzer, 12 and 28 Vdc power supply. 1) Lamp with sounder and flashing “Fire Alarm” sign. 1) REI door holder electromagnet, holding force 50 kg. 1) Programmable electronic siren or bell with flashing FIRE sign, 90 dB, for indoor use; 24 Vdc power supply. IP 31. 1) Self-powered external flashing siren with 1 Fiamm 12 V, 2 Ah battery. Product assembled and selected at the Securvera plant in Rome. Guaranteed by law against manufacturing defects and faults
CE-COMPONENT LIST FOR THE EXPANSION OR INSTALLATION OF A LEGALLY COMPLIANT FIRE ALARM SYSTEM:
01 SF-CFD Conventional 2-zone fire alarm control panel EN54-2 EN54-4 CPD Manages: 64 sensors. Control outputs for alarms, activation and REI doors
02 SF-172 Fiamm 12 V, 7.2 Ah standby accumulator battery L181XH176XP76 mm Valve Regulated AGM VRLA Charged and selected by Securvera
01 SV-RFA Conventional Tyndall-effect smoke detector Current consumption 50 µA in standby, 25 mA in alarm. Plug-in mounting. With 14 mA OC output for repeater
01 SV-RFT Multicriteria Tyndall-effect smoke and fixed-temperature 62 ° C detector. Current consumption 50 µA in standby, 25 mA in alarm. Plug-in base. 14 mA OC output
01 SE-FBI Linear smoke detector for 8 to 100 metres, covered area L. 7+7 metres, power supply 12/28 Vdc, current consumption 35 mA. Opto-relay output 1 A
02 SV-P5R Conventional resettable manual call point, red. Manual request for fire assistance; remains in alarm until reset. IP 40
01 SF-LMP LED and acoustic 85 dB lamp with “Fire Alarm” sign (replaceable), backlit. Wall-mounted installation for fire alarm systems
01 SF-LRS Optical and audible event repeater, LED + 50 dB buzzer, 12 and 28 Vdc power supply, current consumption 22 mA. Connect to detector OC output
01 SF-BE5 White fire-door holding electromagnet, R.E.I. 24 Vdc power supply. Current consumption 50 mA. Holding force 50 kg. With release button
01 SF-SIR Programmable electronic siren or bell with illuminated FIRE sign, 90 dB, signals fire; 24 Vdc power supply. Current consumption 120 mA. IP 31 EN54-3
01 SV-DF2 Red LED external self-powered flashing siren, adjustable alarm duration for fire alarm, 110 dB, 12 and 24 Vdc power supply. IP 31 EN54-3
01 SF-120 Fiamm 12 V, 2.2 Ah standby accumulator battery L178XH34XP60 mm. Valve Regulated AGM VRLA Charged and selected by Securvera
01 SV-GAR Warranty certificate; Securvera manufacturer's warranty as required by law: 24 months; qualified installation compliant with D.M.37/2008 for life
01 SV-IST Detailed assembly instructions and specifications. Current fire regulations on risk assessment must be observed
Securvera Registered Trademark 663069: Automation, Access Control, Wired and Wireless Alarm Sensors, Fire Alarm Systems
Instructions or Installation Manual: See below for the text “CLICK TO GET THE GUIDE OR MANUAL”
Use and Functions: Fire alarm system control panel, activation, response and shutdown
Italian manufacturer of CE products: Fire alarm control panels, smoke and temperature detectors, sounders
Electrical protection against stress: Reverse polarity, sensor life monitoring, line isolators
Country of origin and manufacture: Made in Italy at the Securvera factory and carefully selected
Payment methods or systems: State tax deductions or tax accounting via traceable bank transfer
Warranty beyond the statutory period: Product guaranteed by Securvera for life against manufacturing defects and faults
Compatibility with other brands: Smoke, flame and temperature detectors, conventional systems
Installation instruction manual: Read the manual carefully for weights, measurements, functions and required accessories
Product model/type code: SV-RLBRBQLGNC Fire alarm system kit for workshop and office control
CLICK HERE TO DOWNLOAD THE MANUAL OR PRACTICAL DIY GUIDE:
MANUFACTURER'S MANUAL
24-month warranty
eb: 234532684346