Conventional Fire System Kit Central Office Securvera Sv-rlbrbqlgnd

Save €59,16

Model: eb-224964033146
Warranty: 24 months
Supplier: Securvera
Price:
€1.124,04 €1.183,20

Do you need documentation for this product (installation, configuration, and programming)?

Do you need a direct management contact for large orders?

Do you need help with this product? Contact us
Whatsapp-Share

Share this product
Email-Share Whatsapp-Share Facebook-Share Copy-Share

Shipping

Shipping in 5-10 business days

Description

CONVENTIONAL FIRE ALARM SYSTEM KIT FOR BOILER ROOM, OFFICE AND GARAGE WITH HEAT AND SMOKE DETECTORS, CALL POINTS, EXTERNAL SIREN AND GSM SOS - SV-RLBRBQLGND

Model SV-RLBRBQLGND

SKU: SV-RLBRBQLGND

SV-RLBRBQLGND fire alarm system kit for a boiler room and adjoining areas. Comprises: 1) Conventional microprocessor-based fire alarm control panel with 2 zones. Each zone supports 20 active detectors (individual detector current consumption: 50 ?A in standby, 25 mA in alarm); plus 12 passive devices, up to a maximum of 32 sensors; as well as call points. For a total of 64 sensors. Barriers, provided they are not powered by the zone. Single-event LED indication. Three access passwords for control and operation at three different authority levels. Zone programming (using the front-panel buttons) in pre-alarm, alarm, test and maintenance modes. Acknowledgeable and disableable outputs: sirens, telephone call. 2 O.C. outputs. Zone alarm repetition. 2 relay outputs for fire alarm and fault. 2 supervised fire pre-alarm outputs. 24Vdc auxiliary power supply. 220 V power supply. 50/60 Hz. Standby battery charger, 27.6 V. 1.5 A. Operating temperature from - 5° to + 45°C. Humidity 95%. IP 40 protection. Painted metal enclosure. Dimensions L350XH290XP95 mm. Weight 3.5 Kg. EN54-2, EN54-4 CPD certified. 2) Fiamm 12 V, 7.2 Ah batteries. 1) Tyndall-effect smoke detector. 1) Multicriteria rate-of-rise heat and Tyndall-effect smoke detector. Linear smoke detector for 8 to 100 metres, coverage area L. 7+7 metres, power supply 12/28 Vdc, current consumption 35 mA. Opto-relay output 1 A. 2) Resettable manual call points. 1) Optical and audible event repeater, LED + 50 dB buzzer, 12 and 28 Vdc power supply. 1) Flashing lamp with sounder and “Fire Alarm” sign. 1) REI door-holding electromagnet, pull force 50 Kg. 1) Self-powered external flashing siren with 1) Fiamm 12 V, 2 Ah batteries. 1) GSM SOS call system, telephone dialler with alarm message. Product assembled and selected at the Securvera facility in Rome. Guaranteed by law against manufacturing defects and faults


LIST OF CE-COMPLIANT COMPONENT/S FOR EXPANDING OR INSTALLING A FIRE ALARM SYSTEM IN ACCORDANCE WITH THE LAW:
01 SF-CFD Conventional Fire Alarm Control Panel, 2 Zones, EN54-2 EN54-4 CPD. Manages: 64 sensors. Control outputs for alarm, activation and REI doors
02 SF-172 Fiamm 12 V, 7.2 Ah battery. Standby accumulator L181XH176XP76 mm, Valve Regulated AGM VRLA, charged and selected by Securvera
01 SV-RFA Conventional Tyndall-effect smoke detector. Current consumption 50 µA in standby, 25 mA in alarm. Plug-in mounting. With 14 mA OC output for repeater
01 SV-RFT Multicriteria Tyndall-effect smoke and fixed-temperature detector, 62 ° C. Current consumption 50 µA in standby, 25 mA in alarm. Plug-in base. 14 mA OC output
01 SE-FBI Linear smoke detector for 8 to 100 metres, coverage area L. 7+7 metres, power supply 12/28 Vdc, current consumption 35 mA. Opto-relay output 1 A
02 SV-P5R Resettable conventional manual call point, red. Manual fire emergency call. Remains in alarm until reset. IP 40
01 SF-LMP LED and audible alarm, 85 dB, with backlit “Fire Alarm” sign (replaceable). Wall-mounted installation for fire alarm system
01 SF-LRS Optical and audible event repeater, LED + 50 dB buzzer, 12 and 28 Vdc power supply, current consumption 22 mA. Connect to detector OC output
01 SF-BE5 Fire door holding electromagnet, R.E.I., white, 24 Vdc power supply, current consumption 50 mA, pull force 50 Kg. With release button
01 SV-DF2 Red LED flashing siren, self-powered, external, adjustable timer for fire alarm, 110 dB, 12 and 24 Vdc power supply. IP 31 EN54-3
01 SF-120 Fiamm 12 V, 2 Ah battery. Standby accumulator L178XH34XP60 mm. Valve Regulated AGM VRLA, charged and selected by Securvera
01 SV-CAG GSM telephone call system. 1 alarm input calls and sends a message to 10 numbers. 1 potential-free relay for remote activation of an intervention
01 SV-GAR Warranty certificate; Securvera manufacturer's warranty as required by law: 24 months; lifetime warranty for qualified installation compliant with D.M.37/2008
01 SV-IST Detailed installation instructions. Current fire safety regulations on risk assessment must be observed


Securvera Registered Trademark 663069: Automation, access control, wired and wireless alarm sensors, fire alarm systems
Instructions or Installation Manual: See below for “CLICK TO GET THE GUIDE OR MANUAL”
Use and Application of Functions: Fire Alarm System Control Panel, Activation, Response and Shutdown
Italian Manufacturer of CE Products: Fire Alarm Control Panels, Smoke and Temperature Detectors, Call Points, Sirens
Electrical Protection Against Stress: Reverse polarity, sensor life monitoring, line isolators
Country of Origin and Manufacture: Made in Italy at the Securvera factory and carefully selected
Payment Methods or Systems: Tax deductions or accounting records via traceable bank transfer
Warranty Beyond the Statutory Period: Securvera provides a lifetime warranty against manufacturing defects and faults
Compatibility with Other Brands: Smoke, flame and temperature detectors, call points, conventional systems
Installation Instruction Manual: Read the manual carefully for weights, dimensions, functions and required accessories
Item Code, Model, Type: SV-RLBRBQLGND Fire Alarm System Kit for Garage and Office Control


CLICK HERE TO DOWNLOAD THE MANUAL OR PRACTICAL DIY GUIDE:
MANUFACTURER'S MANUAL

24-month warranty

eb: 224964033146